Can 2 50A Breakers Feed a 100A Contactor? A Comprehensive Guide

Can 2 50A Breakers Feed a 100A Contactor? A Comprehensive Guide

When it comes to electrical systems, proper circuit sizing and breaker coordination are critical to ensuring the safety and functionality of your electrical setup. One common question is whether you can use 2 50A breakers to supply a 100A contactor. This article will explore the potential risks and provide guidance on the best practices to follow.

Understanding 100A Contactors and the Limitations of 50A Breakers

A 100A contactor is designed to handle a nominal current of 100A. However, attempting to supply a 100A contactor with just 2 50A breakers can lead to significant issues, including hazardous surges and potential damage to equipment.

Parallel Connection Without Proper Load Distribution

One way to seemingly resolve the issue is to connect the two 50A breakers in parallel. This method is not recommended because it can cause issues during a surge condition. If one of the breakers trips during a surge, the entire current would momentarily switch to the remaining 50A breaker. This sudden surge can exceed its rated capacity and cause damage to both the breaker and the connected load.

Importance of Safety and Proper Clearance Time

Circuit breakers are safety devices, not just plain switches. They are designed with clearance time in mind, which is the time it takes for the breaker to interrupt the current and isolate the faulty circuit. This clearance time is crucial for safety reasons. A sudden surge can lead to extended exposure of the load to higher currents, increasing the risk of fire or equipment failure.

Best Practices for Sizing Circuit Breakers and Contactors

To ensure a safe and effective electrical system, it's important to follow proper guidelines for sizing both circuit breakers and contactors. Here are some key points to consider:

Surge and Overload Protection

Surges and overloads are common occurrences in electrical systems, especially when starting motors or handling reactive loads. It is essential to consider these factors when selecting the appropriate breakers and contactors to prevent damage to equipment and ensure the integrity of the electrical system.

Motor HP Table for Sizing

The motor HP (horsepower) table provides a valuable resource for sizing upstream circuit breakers and safety switches. This table helps ensure that the selected circuit breakers can handle the starting and running currents of the motor without tripping unnecessarily.

Clearance and Coordination

Proper clearance and coordination are crucial when using multiple breakers in a system. Breakers should be sized and coordinated to ensure that they trip appropriately and provide adequate protection without causing unnecessary tripping or extending the time a surge current flows.

Conclusion

In summary, using 2 50A breakers to supply a 100A contactor is not advised due to the risks of surge and overcurrent, which can lead to equipment damage and potential safety hazards. Instead, it is recommended to follow the proper sizing and coordination guidelines to ensure a safe and reliable electrical system. Always consult the appropriate motor HP table and follow industry best practices to maintain the integrity and safety of your electrical infrastructure.